Wide InfraRed temperature range: -58° to 1922°F (-50 to 1050 °C)
High 30:1 distance to target ratio, laser pointer for easy targeting
Type K input for surface temperature measurements: -58 to 2498°F (-50 to 1370°C)
Manual or Automatic emissivity using type K probe for accurate measurements on different surfaces
Adjustable high/low alarm alerts user visually and audibly when temperature exceeds programmed limits
Built-in memory with recall for 20 readings
MAX/MIN/AVG/DIF functions
NIST Certificate
Transmitter Base with tripod mount
Remote Receiver with USB cable
Type K probe (-22 to 572°F/-30 to 300°C)
Tripod
Analog output cable
PC software
9V battery
100-240VAC adaptor
Hard carrying case
Extech 42560 Specifications | |
---|---|
Range (IR) | -58° to 1922° F (-5° to 1050° C) |
Range (Type K) | -58° to 2498° F (-50° to 1370° C) |
Accuracy (IR) | 2% rdg from -4° to 1000° F (-20° to 538° C) 3.5% rdg above 1000° F (538° C) |
Accuracy (Type K) | ±(1.5% rdg +5° F/3° C) from -58 to 1832° F (-50° to 1000° C) ±(1.5% rdg +3.6° F/2° C) from 1832 to 2498° F (1000° to 1370° C) |
Emissivity | 0.1 to 1.00 adjustable |
Field of View | 30 to 1 |
Dimensions | 3.9x2.2 x9” (100x56x230mm) |
Weight | 10.2oz (290g) |